TM 5-3805-254-20-2
AIR COMPRESSOR GOVERNOR TO WET AIR RESERVOIR LINES AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
25.
Connector (10)
Adapter (12)
Screw on and tighten using 9/16-inch and
7/16-inch open-end wrenches.
26.
Adapter (12)
Wrap pipe threads with antiseizing tape.
27.
Air line (13)
Adapter (12) and
a.
Screw on and tighten using 5/8-inch and
line nut (14)
9/16-inch open-end wrenches.
b.
Take tag off air line.
c.
Get rid of tag.
28.
Clamp (15)
Put on and aline holes in two clamps (16).
29.
Clamps (15 and 16)
Screw (17), new
Screw on and tighten using 7/16-inch box-
lockwasher (18),
end and 7/16-inch open-end wrenches.
and nut (19)
30.
Air compressor
Adapter (21)
Wrap pipe threads with antiseizing tape.
governor (20)
31.
Adapter (21) and
Screw on and tighten using 5/8-inch open-
line nut (22)
end wrench.
NOTE
FOLLOW-ON MAINTENANCE: Close left side hood panel (page 2-424).
TASK ENDS HERE
TA244365
Change 1 2-1051