TM 5-3805-254-20-2
CAB FLOOR THROUGH CONNECTOR TO DOUBLE CHECK VALVE HOSE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
14.
Top of cab floor (1)
Anchor coupling (2)
Put in.
NOTE
Assistance will be needed when performing step 15.
15.
Anchor coupling (2)
Flat washer (3) and
Screw on and tighten using 1 1/8-inch and
nut (4)
1-inch open-end wrenches.
16.
Cab floor through-
a.
Wrap both male pipe threads with anti-
connector 90-degree
seizing tape.
elbow (5)
b.
Screw in and tighten using 9/16-inch
open-end wrench.
Position to face left cab door.
17.
Cab floor through-
Air line (6)
Screw on and tighten using 5/8-inch open-
connector 90-degree
end wrench.
elbow (5)
18.
Left side rear cab
Air line (8) and
a.
Push air line through hole in left lower
wall (7)
left lower rear
rear molding.
molding (9)
b.
Put left lower rear molding in position.
19.
Left lower rear
Eight screws (10)
Screw in and tighten using number two
molding (9)
and eight flat
cross-tip screwdriver.
washers (11)
TA244402
2-1113