TM 5-3805-254-20-2
HEATER CORE HOSES - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
17.
Outlet hose (1)
Hose clamp (2)
Using 1/4-inch flat-tip screwdriver,
loosen.
18.
Shutoff valve (3)
Outlet hose (1) and
Take off.
hose clamp (2)
19.
Screw (4)
Clamp (5), lock-
a.
Using 1/2-inch box-end wrench, un-
washer (6), and
screw and take off.
nut (7)
b.
Take off clamp.
c.
Get rid of lockwasher.
TA244523
2-1309