TM 5-3805-264-13&P
0017
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
NOTE
16
After
Air Reservoir
(M917A1 with
Perform the following After PMCS check
MCS and
with engine off.
M917A2 with
MCS)
Pull cable pull (Figure 13, Item 1) and drain air
reservoir. Release cable pull when all air has drained.
Figure 13. Tailgate Cable Pull.
WARNING
17
Weekly
Hydraulic
System
NEVER work under a raised dump body
unless it is secured in the raised position
with body props and dump body is EMPTY.
Failure to comply may result in personnel
injury or death.
1. Raise dump body and support with body props
03/15/2011Rel(1.10)root(pmcswp)wpno(I1000226413)