TM 5-3805-254-20-1
ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
Q-QUARTERLY
S-SEMIANNUALLY
A-ANNUALLY
B-BIENNIALLY
MI-MILES
ITEM TO BE INSPECTED
Item
Interval
PROCEDURE: CHECK FOR AND HAVE REPAIRED, FILLED,
No.
Q
S
A
B
MI
REPLACED, OR ADJUSTED AS NEEDED
16
.
DRY AIR RESERVOIR
á
·
a.
Check for leaks at draincocks (1).
(1) If draincocks are open, turn clockwise to close.
(2) If draincocks are defective, replace (page 2-1034).
á
b.
Check for loose, cracked, or missing holddown
straps (2).
(1) If holddown straps are loose, tighten using 9/16-
inch, 1/2-inch drive deep socket, 6-inch extension,
and ratchet handle.
(2) If holddown straps are cracked, broken, or missing,
replace (page 2-975).
2-37