TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 25
Check for 11 to 13 vdc at fuse panel (1) as follows: Set multimeter 20 vdc scale. Connect red test
lead to output terminal (11) and black test lead to ground. Have assistant rotate KEY SWITCH (3)
clockwise to on position and press ENGINE START button (4) for 20 seconds. Check for 11 to 13
vdc on multimeter. Have assistant rotate KEY SWITCH (3) counterclockwise to off posistion.
Disconnect test leads.
a
If multimeter reads no voltage, go to step 26.
b
If multimeter reads 11 to 13 vdc, go to step 27.
2-83