TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
27. GENERATOR DOES NOT CHARGE - CONTINUED
Step 2.
Check generator belts (1) for loose, worn, or broken condition.
a.
If generator belts (1) are loose, tighten (page 2-665).
b.
If generator belts (1) are worn or broken, replace (page 2-665).
c.
If generator belts (1) are not loose, worn, or broken, go to step 3.
Step 3.
Using generator and voltage regulator test set and engine electrical system test adapter set, check
generator (2) for proper output. Equipment Description and Data, page 1-19).
a.
If generator (2) is defective, replace (page 2-667).
b.
If internal voltage regulator in generator (2) is defective, replace generator (2) (page 2-667).
c.
If internal voltage regulator in generator (2) is out of adjustment, adjust, notify Direct Support
Maintenance.
d.
If internal voltage regulator and generator (2) are not defective, notify Direct Support Maintenance.
2-214