TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
71.
AIR SYSTEM DOES NOT HOLD AIR PRESSURE - CONTINUED.
Step 3.
Check pressure relief valve (1) in wet air reservoir (2) for broken or frozen spring (3), or bent,
dented, or cracked cap (4).
a. If pressure relief valve (1) is damaged, notify Direct Support Maintenance.
b. If pressure relief valve (1) is not damaged, go to step 4.
Step 4.
Check wet air reservoir (2) for leaks.
a. If wet air reservoir (2) is leaking, replace (page 2-986).
b. If wet air reservoir (2) is not leaking, go to step 5.
2-374