TM 5-3805-254-20-1
RADIATOR OUTLET HOSE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
2.
Connection (1)
Hose (2) and
Take off.
clamp (3)
3.
Outlet (4)
Hose (5) and
Take off.
clamp (6)
4.
Pipe (7)
Hoses (2 and 5) and
a.
Using 1/4-inch flat-tip screwdriver,
clamps (8 and 9)
loosen clamps.
b.
Take off hoses and clamps.
5.
Radiator (10)
Four screws (11),
a.
Using 9/16-inch box-end wrench, un-
four flat washers
screw and take out.
(12), four lock-
b.
Take off outlet.
washers (13), gasket
c.
Get rid of lockwashers.
(14), and outlet (4)
d.
Using gasket scraper, scrape off all old
gasket material.
e.
Get rid of gasket.
CLEANING
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-424).
6.
All rubber parts
a.
Clean with solution of liquid detergent
and water.
b.
Rinse in clean water.
c.
Using clean, dry rags, wipe dry.
WARNING
Dry-cleaning solvent P-D-680 is toxic and flammable. Wear protective safety goggles and gloves
and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and do not
breathe vapors. Do not use near open flame or excessive heat. The flashpoint for type #1 dry-
cleaning solvent is 100°F (38°C) and for type #2 is 138°F (59°C). If you become dizzy while using
cleaning solvent, get fresh air immediately, and get medical aid. If contact with eyes is made,
flush your eyes with water and get medical aid immediately.
7.
Outlet (4), pipe
a.
Clean with dry-cleaning solvent.
(7), and clamps
b.
Using clean, dry rags, wipe dry.
(3,6, 9, and 8)
2-640