TM 5-3805-254-20-2
IGN SYSTEM STARTER CIRCUIT BREAKER - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
CAUTION
Use care when working behind instrument panel to prevent breaking or disconnecting wires.
1.
Mounting
Two screws (2), two
a.
Using two 7/16-inch box-end wrenches,
bracket (1)
lockwashers (3), and
unscrew and take out.
two nuts (4)
b.
Get rid of lockwashers.
2.
Circuit breaker (5)
Rubber boot (6)
Pull off and slide back.
3.
Two wires (7), two
a.
Tag wires (page 2-424).
screws (8), and two
b.
Using 3/8-inch flat-tip screwdriver, un-
lockwashers (9)
screw and take out.
c.
Get rid of lockwashers.
4.
Lower instrument
Circuit breaker (5)
Take out.
panel support (10)
INSTALLATION
CAUTION
Use care when working behind instrument panel to prevent breaking or disconnecting wires.
5.
Lower instrument
Circuit breaker (5)
Put in place and hold.
panel support (10)
6.
Circuit breaker (5)
Two wires (7), two
a.
Put wires in correct position.
screws (8), and two
b.
Screw in and tighten using 38-inch flat-
new lockwashers (9)
tip screwdriver.
c.
Take off tags.
d.
Get rid of tags.
7.
Rubber boot (6)
Slide down and put on.
8.
Mounting
Two screws (2), two
Screw in and tighten using two 7116-inch
bracket (1)
new lockwashers (3),
box-end wrenches.
and two nuts (4)
2-770