TM 5-3805-254-20-2
BATTERY POSITIVE CABLE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DISASSEMBLY
8
Two terminals (1)
Two screws (2)
Using two 1/2-inch open-end wrenches,
and two nuts (3)
unscrew and take out.
9
Two cables (4)
Two terminals (1),
Using two 9/16-inch open-end wrenches,
two screws (5),
unscrew and take out.
and two nuts (6)
10
Two coverings (7)
Take off.
CLEANING
WARNING
Improper cleaning methods and use of unauthorized cleaning liquids or solvents can injure personnel and cause
damage to equipment Refer to TM 9-247.
For more information on how to clean parts, go to General Maintenance Instructions (page 2-424).
11
Two posts (8)
a
Using weak solution of bicarbonate
soda, water and wiping rags, clean.
b
Using wiping rags, dry.
c
Using battery terminal cleaner, clean.
12
Two terminals (1)
a
Using weak solution of bicarbonate
soda, water and wiping rags, clean.
b
Using wiping rags, dry.
c
Using battery terminal cleaner, clean.
13
Four screws (2
a
Using weak solution of bicarbonate
and 5), four nuts
soda, water and wiping rags, clean.
(3 and 6), and
b
Using wiping rags, dry.
two cables (4)
14
Two coverings (7)
a
Using liquid detergent and water, clean.
and two clamps (9)
b
Using wiping rags, dry.
2-832