TM 5-3805-254.20-2
GENERATOR AND REGULATOR - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
ADJUSTMENT
NOTE
Adjust generator if ampere output is not within 10 percent of rated output stamped on generator.
Go to Troubleshooting (page 2-43).
17.
Connector body (1)
Voltage adjustment
a.
Take out.
cap (2)
b.
Rotate 90-degrees clockwise to raise
ampere output, and counterclockwise to
lower ampere output.
c.
Put in.
NOTE
FOLLOW-ON MAINTENANCE:
1. Connect battery ground cable (page 2424).
2. Close right side hood panel (page 2-424).
TASK ENDS HERE
TA244130
2-670