TM 5-3805-254-20-2
AMMETER - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL - CONTINUED
2.
Ammeter (1)
Nut (2), lockwashers
a.
Tag wire (page 2-424).
(3), and wire (4)
b.
Using 5116-inch box-end wrench, un-
screw and take out.
c.
Get rid of lockwasher.
3.
Two nuts (5), two
a.
Tag wire (page 2-424).
lockwashers (6),
b.
Using 3/8-inch box-end wrench, un-
and wire (7)
screw and take out.
c.
Get rid of lockwashers.
4.
Mounting bracket (8)
Take off.
5.
Upper center instru-
Ammeter (1)
Take out.
ment panel (9)
INSPECTION/REPLACEMENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-424).
6.
Ammeter (1)
a.
Look for cracks or dents.
b.
Check to see if gage is readable.
7.
Mounting bracket (8)
Look for bends or breaks.
8.
All threaded parts
Look for damaged threads or rounded nuts.
INSTALLATION
CAUTION
Use care when working behind upper center instrument panel to prevent breaking or disconnecting wires.
9.
Upper center instru-
Ammeter (1)
Put in and hold.
ment panel (9)
Position as shown.
2-732