TM 5-3805-254-34
6-6.
TORQUE CONVERTER COOLER MAINTENANCE.
This Task Covers:
a. Removal
d.
Assembly
b. Disassembly
e.
Installation
c. Cleaning and Inspection
Initial Setup:
Equipment Conditions:
Materials/Parts:
Hood removed (see TM 5-3805-254-20).
Sealant compound (Item 19, Appendix B)
Thermostat removed (see TM 5-3805-254-20).
Dry cleaning solvent (Item 23, Appendix B)
Radiator bypass coolant line removed (see TM 5-
One gasket
3805-254-20).
Seventeen lockwashers
Front water manifold hose removed (see TM 5-3805-
254-20).
Personnel Required: Two
Tools/Test Equipment:
General Safety Instructions:
General mechanics tool kit
Field automotive shop set
Dry cleaning solvent is flammable and must not be
used near open flame. Use only In a well-ventilated
area.
a.
REMOVAL
WARNING
Torque converter cooler is heavy. DO NOT remove nuts and screws unless auxiliary transmission Is
supported. Failure to follow this warning may result in Injury or death to personnel.
1.
Remove plug (3) and drain torque converter cooler (1).
2.
Remove four nuts (5), lockwashers (4), screws (2), and torque converter cooler (1) from support (6). Discard
lockwashers.
6-42