TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 6.Test jumper wire (8) as follows: Using multimeter, set to ohms scale and adjust to 0 ohms.
Connect red test lead to terminal (3) on stoplight switch (1) and black test lead to terminal (9) on
stoplight switch (7). Check for 0 ohms on multimeter. Disconnect test leads.
a.If multimeter reads no continuity, jumper wire (8) must be replaced. Notify Direct
Support Maintenance.
b.
If multimeter reads 0 ohms, connect batteries (page 2-
424) and go to step 7.
2-277