TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 4.Set multimeter to 20 vdc scale. Connect red test lead to wire terminal (9) and black test
lead to ground. Check for 11 to 13 vdc on multimeter. Disconnect test leads.
a.
If multimeter does not read 11 to 13 vdc, 62 wire (10)
must be replaced.
b.
If multimeter reads 11 to 13 vdc, go to step 5.
Step 5. Set multimeter to 20 vdc scale. Connect red test lead to wire terminal (11) and black test
lead to ground. Check for 11 to 13 vdc on multimeter. Disconnect test leads.
If multimeter does not read 11 to 13 vdc, DOME/PNL light switch (2) must be replaced
(page 2-722).
2-301