ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 12
Check wire (5) from NO terminal (2) on oil pressure switch (1) to fuel solenoid (8) for broken
condition as follows: Disconnect batteries (page 2-424). Using 3/16-inch flat-tip screwdriver,
loosen screw (7) and take off wire (5). Set multimeter to ohms scale and adjust to 0 ohms.
Connect red test lead to wire terminal (9) and black test lead to ground. Check for 0 ohms on
multimeter. Disconnect test leads.
If multimeter reads no continuity, wire (5) must be replaced. Notify Direct Support
Maintenance.