Step 14 Check for 11 to 13 vdc to fuse panel
ENGINE CRANKS BUT FAILS TO START ABOVE 50F (18C) - CONTINUED - TM-5-3805-254-20-1_147
TM-5-3805-254-20-1 Truck Dump 20-Ton 6x4 On-Off Highway 71 000 GVW IHC Model F-5070 (CCE) Manual
Page Navigation
126
127
128
129
130
131
132
133
134
135
136
TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
a
If
multimeter
reads no continuity, replace fuse (7).
b
If
multimeter
reads 0 ohms, go to step 16.