TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2.
Remove instrument panel pad (page 2-424). Set multimeter to 20 vdc scale. Connect red test lead to
circuit breaker strip feed stud (3) and black test lead to ground. Check for 11 to 13 vdc on multimeter.
Disconnect test leads.
a.
If multimeter does not read 11 to 13 vdc go to step 3.
b.
If multimeter reads 11 to 13 vdc, go to step 9.
Step 3.
Set multimeter to 20 vdc scale. Connect red test lead to terminal (4) on secondary magnetic switch (5)
and black test lead to ground. Check for 11 to 13 vdc on multimeter. Disconnect test leads.
a.
If multimeter does not read 11 to 13 vdc go to step 5.
b.
If multimeter reads 11 to 13 vdc, go to step 4.
TA243798