TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
a. If multimeter does not read 11 to 13 vdc, go to step 4.
b. If multimeter reads 11 to 13 vdc, go to step 5.
Step 4. Test fuse (6) as follows: Remove fuse (6). Using multimeter, set to ohms scale
and adjust to 0 ohms. Connect red test lead to fuse end (7) and black test lead to
fuse end (8). Check for 0 ohms on multimeter. Disconnect test leads.
a. If multimeter reads no continuity, replace fuse (6) (page 2-664).
b. If multimeter reads O ohms, install fuse (6) and go to step 5.
2-247