TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 4.
Unscrew and take out two wing screws (17) and take off cover (18). Using multimeter set to 20
vdc scale, connect red test lead to 15 terminal (19) on fire wall junction box (20) and black test
lead to ground. Check for 11 to 13 vdc on multimeter. Disconnect test lead.
a. If multimeter does not read 11 to 13 vdc, go to step 6.
b. If multimeter reads 11 to 13 vdc, wire (21) must be replaced, notify Direct Support
Maintenance.
2-307