TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
b. If corroded, using number one cross-tip screwdriver, unscrew and take off screw (9),
lockwasher (10) and wire terminal (6) from terminal stud (7). Clean wire terminal (6)
and terminal stud (7) using wire brush. Place wire terminal (6), lockwasher (10) and
screw (9) on terminal stud (7) and tighten using number one cross-tip screwdriver.
Put power take off cover plate (11) and two screws (12) in place and screw in and
tighten using number one cross-tip screwdriver. Put insulation (13) and floor mat
insert (14) in place. Put cover (15) in place and screw on and tighten two wing
screws (16).
c.
If not loose or corroded, replace power take off light switch (8) (page 2-693). Put
lamp (17) in lamp socket (18). Push in, turn clockwise and release. Push lamp
socket (18) into power take off indicator (19)
2-309