MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 7.
Check air shaft control input hose (11) for loose, cracked, broken, or kinked
condition.
a.
If air shift control input hose (11) is cracked, broken, or kinked,
input hose must be replaced. Notify Direct Support Maintenance.
b.
If air shift control input hose (11) is loose, tighten using 7/16-inch
open-end wrench.
2-423