TM 5-3805-254-20-1
ACCESS PROCEDURES - CONTINUED
UPPER CENTER INSTRUMENT PANEL
Opening
WARNING
Batteries must be disconnected before working near electrical components. Failure to observe
this precaution could cause serious injury or damage to equipment.
1.
Disconnect battery cables (page 2-444).
2.
Using cross-tip screwdriver, take out eight screws (1).
CAUTION
Do not pull instrument panel out too far, light bulbs could be pulled from sockets or wires broken.
3.
Open upper center instrument panel (2).
Closing
4.
Place upper center instrument panel (2) in position.
5.
Screw in and tighten eight screws (1) using cross-tip screwdriver.
6.
Connect battery cables (page 2-444).
2-439