TM 5-3805-254-20-1
ACCESS PROCEDURES - CONTINUED
INSTRUMENT PANEL PAD
Removal
WARNING
Batteries must be disconnected before working near electrical components. Failure to observe
this precaution could cause serious injury or damage to equipment.
1.
Disconnect battery cables (page 2-444).
2.
Open right instrument panel (1) (page 2-437).
3.
Turn three captive thumbscrews (2) counterclockwise until fully loosened.
4.
Lower instrument panel pad (3) and move to left to disconnect from two hinges (4).
5.
Remove instrument panel pad (3).
Installation
6.
Aline two hinges (4) and move instrument panel pad (3) to right to secure.
7.
Raise instrument panel pad (3) to closed position.
8.
Turn three captive thumbscrews (2) clockwise to lock.
9.
Close right instrument panel (1) (page 2-437).
10.
Connect battery cables (page 2-444).
2-440