TM 5-3805-254-20-1
AIR FILTER ELEMENT - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
WARNING
Improper cleaning methods and use of unauthorized cleaning liquids or solvents can injure
personnel and cause damage to equipment. Refer to TM 9-247.
Particles blown by compressed air are hazardous. Make certain the airstream is directed away
from user and other personnel in the area. Compressed air used for cleaning purposes shall not
exceed 30 psi (207 kPa). User must wear safety goggles or face shield to prevent injury to
personnel.
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-424).
12.
Air cleaner housing
Using air hose assembly and air blow gun,
and ejection valve
clean inside.
INSPECTION/REPLACEMENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-
424).
13.
Air cleaning housing
Look for damaged, broken, or cracked
and ejection valve
areas.
ASSEMBLY/INSTALLATION
WARNING
Metal edges of air cleaner housing are sharp, care must be taken to prevent personal injury.
14.
Air hose (1)
Hose clamp (2)
Put on.
15.
Air cleaner
Air hose (1)
Push on.
housing (3)
2-464