TM 5-3805-254-20-2
BATTERY NEGATIVE CABLE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
DISASSEMBLY
8.
Two terminals (1)
Two screws (2) and
Using two 1/2-inch open-end wrenches,
two nuts (3)
unscrew and take out.
9.
Two cables (4)
Two terminals (1),
Using two 9/16-inch open-end wrenches,
two screws (5),
unscrew and take out.
and two nuts (6)
CLEANING
WARNING
Improper cleaning methods and use of unauthorized cleaning liquids or solvents can
injure personnel and cause damage to equipment. Refer to TM 9-247.
NOTE
For more information on how to clean parts, go to General Maintenance Instructions
(page 2-424).
10.
Two posts (7)
a.
Using weak solution of bicarbonate
soda, water and wiping rags, clean.
b.
Using wiping rags, dry.
c.
Using battery terminal cleaner, clean.
11.
Two terminals (1)
a.
Using weak solution of bicarbonate
soda, water and wiping rags, clean.
b.
Using wiping rags, dry.
c.
Using battery terminal cleaner, clean.
12.
Four screws (2
a.
Using weak solution of bicarbonate
and 5), four nuts
soda, water and wiping rags, clean.
(3 and 6), and
b.
Using wiping rags, dry.
two cables (4)
WARNING
Safety goggles must be worn when using wire brush. Flying rust or metal particles could
cause eye injury.
13.
Left frame
Cable ground
a.
Using pocket knife, scrape clean.
rail (8)
area (9)
b.
Using wire brush, clean.
2-826