TM 5-380-254-20-2
NEUTRAL SAFETY SWITCH - CONTINUED
INITIAL SETUP
Tools
Personnel Required
Container, 6-gallon
One
Wrench, open-end, 7/8-inch
Materials/Parts
Rags, wiping (item 15, appendix C)
Tape, antiseizing (item 22, appendix C)
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
1
Neutral safety
Two wires (2)
Pull apart.
switch (1)
2
Transmission (3)
Neutral safety
a
Place 6-gallon container underneath.
switch (1)
b
Using 7/8-inch open-end wrench, un-
screw and take out.
TA244145
2-691