TM 5-3805-254-20-2
CHASSIS T-FITTING TO DOUBLE CHECK VALVE HOSE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSTALLATION
CAUTION
Antiseizing tape must be used on all pipe threads to provide a good seal and to prevent threaded parts
from seizing.
NOTE
For more information on how to use antiseizing tape, go to General Maintenance Instructions (page 2-
424).
6.
Double check
45-degree elbow (3)
Wrap pipe threads with antiseizing tape.
valve (6)
7.
45 degree elbow (3)
Screw on and tighten using 3/4-inch open-
and line nut (4)
end wrench.
8.
Chassis
Fitting (1)
Wrap pipe threads with antiseizing tape.
T-fitting (7)
9.
Fitting (1) and
Screw on and tighten using 3/4-inch and
line nut (2)
5/8-inch open-end wrenches.
TASK ENDS HERE
TA244420
Change 1 2-1145