TM 5-3805-254-20-2
PUMP BYPASS HOSE AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
WARNING
Drycleaning solvent P-D-680 is toxic and flammable Wear protective safety goggles and gloves and use only
in a well-ventilated area Avoid contact with skin, eyes, and clothes and do not breathe vapors Do not use
near open flame or excessive heat The flashpoint for type #1 drycleaning solvent is 1000F (380C) and for
type #2 is 138°F (590C) If you become dizzy while using cleaning solvent, get fresh air immediately, and get
medical aid If contact with eyes is made, flush your eyes with water and get medical aid immediately.
Improper cleaning methods and use of unauthorized cleaning liquids or solvent can injure personnel Refer to
TM 9-247.
NOTE
Hoses and fittings must be cleaned thoroughly.
For more information on how to clean parts, go to General Maintenance Instructions (page 2-424).
8
All metal parts
Using drycleaning solvent, clean
thoroughly.
9
Hose (1)
Using detergent and water, clean
thoroughly.
WARNING
Particles blown by compressed air are hazardous Make certain the air stream is directed away from user and
other personnel in the area Compressed air used for cleaning purposes shall not exceed 30 psi (207 kPa)
User must wear safety goggles or face shield to prevent injury to personnel.
10
All parts
Using air blow gun and air hose assembly,
blow dry.
INSPECTION/REPLACEMENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions
(page 2-424).
Change 1 2-1234