TM 5-3805-254-20-2
TRANSMISSION OIL PRESSURE GAGE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
CAUTION
Use care when working behind instrument panel to prevent breaking or disconnecting wires.
1.
Gage (1)
Light socket (2)
Pull out.
2.
Elbow (3)
Line (4)
Using two 9/16-inch open-end wrenches,
unscrew and take off.
3.
Gage (1)
Elbow (3)
Using 9/16-inch open-end wrench, un-
screw and take off.
4.
Two nuts (5) and
a.
Hold gage.
two lockwashers (6)
b.
Using 318-inch open-end wrench, un-
screw and take off.
c.
Get rid of lockwashers.
5.
Mounting bracket (7)
Take off.
6.
Right instrument
Gage (1)
Take out.
panel (8)
INSPECTION/REPLACEMENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-424).
7.
Gage (1)
a.
Look for cracks or dents.
b.
Check to see if gage is readable.
8.
Mounting bracket (7)
Look for cracks, bends, or breaks.
9.
All threaded parts
Look for damaged threads or rounded
heads.
INSTALLATION
10.
Gage (1)
Wrap pipe threads with antiseizing tape
(page 2-424).
2-1448