TM 5-3805-254-20-2
WATER TEMPERATURE GAGE AND LINE - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
CAUTION
Use care when working behind upper center instrument panel to prevent breaking or disconnecting wires.
Make sure water temperature gage is not disconnected from line Damage to gage will occur.
1
Gage (1)
Light socket (2)
Pull out.
2
Two nuts (3) and
a
Using 3/8-inch open-end wrench, un-
two lockwashers (4)
screw and take off.
b
Get rid of lockwashers.
3
Mounting bracket (5)
Take off.
4
Engine side of
Electrical tiedown
a
Using 6-inch diagonal-cutting pliers,
firewall (6) and
strap (8)
cut off.
bracket (7)
b
Get rid of strap.
5
Front water
Line retainer
Using 5/8-inch and 7/8-inch open-end
manifold (9)
nut (10)
wrenches, unscrew and slide back.
TA244633
2-1470