TM 5-3805-254-20-2
AIR CLEANER VACUUM GAGE
This task covers:
a
Removal (page 2-1466)
c
Installation (page 2-1468)
b
Inspection/Replacement
(page 2-1467)
INITIAL SETUP
Tools
Personnel Required
Wrench, open-end, 3/8-inch
One
Wrench, open-end, 9/16-inch
(two required)
Equipment Condition
Wrench, open-end, 3/4-inch
Left side cab door opened (page 2-424).
Right instrument panel opened (page 2-424).
Lockwasher, gage (two required)
Tape, antiseizing (item 22, appendix C)
ACTION
LOCATION
ITEM
REMARKS
REMOVAL
CAUTION
Use care when working behind right instrument panel to prevent breaking or disconnecting wires.
1
Elbow (1)
Using two 9/16-inch open-end wrenches,
Line (2)
unscrew and take off.
2
Adapter (3)
Using 9116-inch and 3/4-inch open-end
Elbow (1)
wrenches, unscrew and take out.
3
Gage (4)
Using 3/4-inch open-end wrench, unscrew
Adapter (3)
and take off.
4
a
Hold gage.
Two nuts (5) and
b
Using 3/8-inch open-end wrench, un-
two lockwashers (6)
screw and take off.
c
Get rid of lockwashers.
5
Take off.
Mounting bracket (7)
2-1466