TM 5-3805-254-20-2
AIR PRESSURE GAGE LINES AND FITTINGS - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
INSPECTION/REPLACEM ENT
NOTE
Replace all damaged or defective parts.
For more information on how to inspect parts, go to General Maintenance Instructions (page 2-424).
10.
Lines (1)
Look for cracks, kinks, or burn holes.
11. Lines (1) and
Flare seats (3)
Look for cracks, dents, or bends.
fittings (2)
12.
All threaded parts
Look for damaged threads or rounded nuts.
INSTALLATION
CAUTION
Use care when performing steps 13 thru 16 to prevent damage to air pressure switches, wires, and lines.
TA244654
2-1494