TM 5-3805-254-34
6-2.
AUXILIARY TRANSMISSION REPAIR (Cont).
b.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, Is toxic and flammable. Always wear protective goggles and
gloves, and use only In a well-ventilated area. Avoid contact with skin, eyes, and clothes, and DO
NOT breathe vapors. DO NOT use near open flame or excessive heat. The solvents flash point Is
100°F-138°F (38°C-59°C). If you become dizzy while using cleaning solvent, Immediately get fresh
air and medical help. If solvent contacts eyes, Immediately wash your eyes and get medical aid.
1.
Clean interior metal parts with dry cleaning solvent.
2.
Clean external metal parts with dry cleaning solvent or steam. Dry thoroughly.
3.
Inspect metal parts for cracks, breaks, wear, and other damage. Replace if damaged.
4.
Inspect bearings for wear or damage. Replace if damaged.
5.
Inspect gears for chipped, worn, or broken teeth.
c.
ASSEMBLY
NOTE
Perform steps 1 through 52 to assemble auxiliary transmission case.
1.
Apply thin coat of sealant compound to threads of pipe plug (86), drain plug (85), plug (84), filler plug (83) and two
plugs (82), and install into case (8).
TA703746
6-16