TM 5-3805-254-34
6-11. TORQUE CONVERTER REPLACEMENT
8.
Remove two bearing retainers (14), converter
pump hub (18), and gasket (19) from converter
pump (11). Discard gasket.
9.
Remove seal ring (15) from converter pump
(11). Discard seal ring.
10.
Remove seal (17) from converter pump hub
(18).
Discard
seal.
b.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective
goggles and gloves, and use only In a well-ventilated area. Avoid contact with
skin, eyes, and clothes, and DO NOT breathe vapors. DO NOT use near open
flame or excessive heat. The solvent's flash point is 100°F-138°F (38°C-590C). If
you become dizzy while using cleaning solvent, Immediately get fresh air and
medical help. If solvent contacts eyes, Immediately wash your eyes and get
medical aid.
1.
Clean metal parts with dry cleaning solvent.
2.
Inspect metal parts for cracks, breaks, wear, or other damage. Replace if damaged.
3.
Inspect bearings for wear or damage (see TM 9-214). Replace if damaged. If bearing (16) in converter pump hub
(18) Is damaged, press out bearing. Press new bearing into converter pump hub ungrooved end first.
4.
Apply thin coat of hydraulic fluid to surfaces of metal parts, bearings, seal ring, and seal.
TA703798
6-75