TM 5-3805-254-34
16-3.
POWER TAKE-OFF REPAIR (Cont).
16.
Press cone (27) off shaft (17).
b.
CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles and
gloves, and use only In a well-ventilated area. Avoid contact with skin, eyes, and clothes, and DO
NOT breathe vapors. DO NOT use near open flame or excessive heat. The solvents flash point is
100°F-138°F (38°C-590C). If you become dizzy while using cleaning solvent, Immediately get fresh
air and medical help. If solvent contacts eyes, Immediately wash your eyes and get medical aid.
1.
Clean metal parts with dry cleaning solvent.
2.
Inspect metal parts for cracks, breaks, wear, and other damage. Replace if damaged.
3.
Inspect gears for chipped, worn, or broken teeth. Replace if damaged.
4.
Inspect shaft splines for chipped, worn, or broken splines. Replace if damaged.
5.
Inspect cones and roller assemblies for wear or damage (see TM 9-214). Replace if damaged.
6.
Apply thin coat of hydraulic fluid to all internal metal parts.
c.
ASSEMBLY
1.
Press cone (27) on shaft (17).
2.
Press roller cup (26) into cap (22).
3.
Press new oil seal (25) into cap (22).
TA704224
16-12