TM 5-3805-254-34
17-4.
HYDRAULIC OIL RESERVOIR REPLACEMENT (Cont).
b. CLEANING AND INSPECTION
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable. Always wear protective goggles and
gloves, and use only In a well-ventilated area. Avoid contact with skin, eyes, and clothes, and DO
NOT breathe vapors. DO NOT use near open flame or excessive heat. The solvents flash point is
100°F-138°F (38°C-590C). If you become dizzy while using cleaning solvent, immediately get fresh
air and medical help. If solvent contacts eyes, Immediately wash your eyes and get medical aid.
1.
Clean hydraulic oil reservoir and parts with dry cleaning solvent.
2.
Inspect hydraulic oil reservoir for dents, cracks, holes, and corrosion. Replace if damaged.
3.
Inspect sight indicator for cracks and clarity. Replace if defective.
4.
Inspect other parts for cracks, corrosion, and other damage. Replace if damaged.
c. INSTALLATION I
1.
Install two elbows (1) to end of hydraulic oil reservoir (2).
2.
Install two nuts (6) and sight indicator (7).
3.
Using floor jack, raise hydraulic oil reservoir (2) and move to vehicle.
4.
Install hydraulic oil reservoir (2) with two straps (3), new lockwashers (4), and nuts (5).
FOLLOW-ON TASKS:
Install hydraulic filter and housing (see TM 5-3805-254-20).
Install reservoir-to-pump suction hose and fittings (see TM 5-3805-254-20).
17-19/(17-20 Blank)