TM 5-3805-254-34
5-2.
STARTER MOTOR TEST (Cont).
3.
Remove two plugs (16) and gaskets (15) from
housing (8). Inspect plugs for damage. Replace if
damaged. Discard gaskets.
4.
Set multimeter to RX1 scale and check continuity
between two brush terminals (11). If multimeter
reads 10 ohms or more, repair starter motor (see
paragraph 5-3).
5.
Set multimeter to RX10,000 scale. Check continuity
between each brush terminal (11) and housing (8).
If multimeter reads anything except infinity, repair
starter motor (see paragraph 5-3).
6.
Set multimeter to RX1 scale. Check continuity
between terminal (19) and B terminal (18). If
multimeter reads more than 10 ohms, replace starter
motor solenoid (see paragraph 5-5).
7.
Set multimeter to RX10,000 scale. Check resistance
between terminal (19) and switch case (17). Check
resistance between M terminal (20) and switch
case. Check resistance between B terminal (18) and
switch case. If multimeter reads anything except
infinity for any checks, replace starter motor solenoid
(see paragraph 5-5).
8.
Install starter motor on alternator and starter
automotive generator test stand. Operate test stand
in accordance with operating instructions.
TA703705
5-12