TM 5-3805-264-13&P
0068
DISASSEMBLY
CAUTION
Ports in reservoir should be plugged to prevent contamination of hydraulic system. Failure
to comply may result in damage to equipment.
1.
Remove hydraulic oil filter service indicator gauge (WP 0069).
2.
3.
Remove four screws (Figure 1, Item 1) and filter housing (Figure 1, Item 13) from hydraulic reservoir
(Figure 1, Item 11).
4.
Remove pipe (Figure 1, Item 12) from filter housing (Figure 1, Item 13).
5.
Remove O-ring (Figure 1, Item 14) from filter housing mounting flange. Discard O-ring.
6.
Separate filter housing (Figure 1, Item 13) and remove O-ring (Figure 1, Item 15). Discard O-ring.
7.
Remove fill cap (Figure 1, Item 2), six screws (Figure 1, Item 3), and strainer (Figure 1, Item 4).
8.
Remove sight tube (Figure 1, Item 6) and two elbows (Figure 1, Item 5).
9.
Remove drain plug (Figure 1, Item 10), elbow (Figure 1, Item 7), hose (Figure 1, Item 8), and cap
(Figure 1, Item 9).
END OF TASK
CLEANING AND INSPECTION
Clean and inspect components in accordance with General Maintenance Instructions (WP 0072).
0068-2