TM 5-3805-274-10
Table 3-2. Troubleshooting Procedures - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
HYDRAULIC SYSTEM (Continued)
4.
BODY WONT RAISE WHEN CONTROL PLACED IN UP POSITION.
Step 1.
Check that PTO is engaged.
Engage PTO (see TM 9-2320-273-10).
Step 2.
Check hydraulic oil level (see Table 3-1, item 15).
Add oil if necessary.
Step 3.
Check mechanical linkage between cab control and control valve for loose connection.
Notify Organizational Maintenance
if linkage is loose.
Step 4.
Check for leaks in the hydraulic components and lines.
Notify Organizational Maintenance
if leaks are evident.
5.
DUMP BODY RESPONSE TO CONTROLS IS SLUGGISH.
Step 1.
Check hydraulic filter service indication gage.
Notify Organizational Maintenance
if gage needle is in the red range.
Step 2.
Check hydraulic oil level (see Table 3-1, item 15).
Add oil if necessary.
Step 3.
Check for leaks.
Notify Organizational Maintenance
if Class III leaks are evident.
3-16