TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
c.
If battery negative (-) cables (5) are frayed, repair (page 2-424) and install battery
box cover (page 2-424).
d.
If battery negative (-) cables (5) are broken, replace (page 2-824).
e.
If battery negative (-) cables (5) are not loose, corroded, frayed, or broken, install
battery box cover (page 2-424) and go to step 9.
Step 9.
Set multimeter to 20 vdc scale. Connect red test lead to BAT terminal (9) on solenoid
(10) and black test lead to ground. Check for 11 to 13 vdc on multimeter. Disconnect
test leads.
a.
If multimeter does not read 11 to 13 vdc, replace battery positive (+) cable (1) (page
2-829).
b.
If multimeter reads 11 to 13 vdc, go to step 10.
2-91