MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 14.
Set multimeter to 20 vdc scale. Connect red test lead to terminal (11) on primary magnetic switch
(12) and black test lead to ground. Have assistant rotate KEY SWITCH (9) clockwise to on position
and press ENGINE START button (10) for 5 seconds. Check for 11 to 13 vdc on multimeter. Have
assistant rotate KEY SWITCH (9) counterclockwise to off position. Disconnect test leads.
a.
If multimeter does not read 11 to 13 vdc, go to step 16.
b.
If multimeter reads 11 to 13 vdc, go to step 15.
2-95