TM 5-380625420-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
a.
If multimeter does not read 11 to 13 vdc, go to step 22.
b.
If multimeter reads 11 to 13 vdc, replace neutral safety switch (3) (page 2-690).
Step 22.
Remove instrument panel pad (page 2-424). Set multimeter to 20 vdc scale. Connect red test lead to
output terminal (13) on ENGINE START button (6) and black test lead to ground. Have assistant
rotate KEY SWITCH (5) clockwise to on position and press ENGINE START button (6) for 5 seconds.
Check for 11 to 13 vdc on multimeter. Have assistant rotate KEY SWITCH (5) counterclockwise to off
position. Disconnect test leads.
a.
If multimeter does not read 11 to 13 vdc, go to step 24.
b.
If multimeter reads 11 to 13 vdc, go to step 23.
TA243777
2-99