TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Place 14B wire (7), 14 wire (6), and 15 wire (5) on output terminal (3) and screw on
and tighten nut (8) using 9/16-inch open-end wrench. Connect batteries and install
instrument panel pad (page 2-424).
c.
If 15 wire (5), 14 wire (6), and 14B wire (7) are not loose or corroded, connect
batteries (page 2-424) and go to step 30.
Step 30.
Set multimeter to 20 vdc scale and connect red test lead to output terminal (3) on secondary magnetic
switch (4), and black test lead to ground. Check for 11 to 13 vdc on multimeter. Disconnect test
leads.
If multimeter reads 11 to 13 vdc, install instrument panel pad (page 2-424).
2-103