TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 29.
Test 53 wire (3) as follows: Set multimeter to 20 vdc scale. With assistant, connect red test lead
to wire terminal (11) on wire connector (12) and black test lead to terminal (10) on junction box
(13). Check for 0 ohms on multimeter. Disconnect test leads.
a. If multimeter reads no continuity, 53 wire (3) must be replaced. Notify Direct Support
Maintenance.
b. If multimeter reads 0 ohms, push wire connectors (12 and 14) together until locked.
Place junction box cover (2) in position and screw on two wing screws (1) and
tighten. Install center instrument panel (page 2-424). Connect batteries (page 2-
424). Go to Malfunction 24, ONE HEADLIGHT DOES NOT WORK (page 2-194).
2-193