MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 27.
Test headlight beam selector switch (9) as follows: Disconnect batteries (page 2-424). Remove
center instrument panel (page 2-424). Pull apart wire connectors (3 and 6). Set multimeter to
ohms scale and adjust to 0 ohms. Connect red test lead to wire terminal (10) and black test lead
to wire terminal (11) on wire connector (6). Check for 0 ohms on multimeter. Disconnect test
leads.
a. If multimeter reads no continuity, replace headlight beam selector switch (1) (page 2-
742).
b. If multimeter reads 0 ohms, go to step 28.
2-191