TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
DUMP BODY
79. DUMP BODY DOES NOT RAISE.
Step 1.
Check oil level in hydraulic oil reservoir (1).
a.
If hydraulic oil level is low, fill (page 2-1375).
b.
If hydraulic oil level is not low, go to step 2.
Step 2.
Check that power take off switch (2) is on.
a.
If power take off (3) is not engaged, perform power take off engage-
ment procedure (TM 5-3805-254-10).
b.
If power take off (3) is engaged, go to step 3.
Step 3.
Check that power take off shaft (4) is turning.
a.
If power take off shaft (4) is not turning, notify Direct Support
Maintenance.
b.
If power take off shaft (4) is turning, go to step 4.
Step 4.
Check reservoir-to-pump suction hose (5) for cracked, leaking, or loose
condition.
a.
If reservoir-to-pump suction hose (5) is cracked or leaking, replace
(page 2-1390).
b.
If reservoir-to-pump suction hose (5) is loose, tighten using 1/4-
inch flat-tip screwdriver.
c.
If reservoir-to-pump suction hose (5) is not cracked, leaking, or
loose, go to step 5.
2-410