TM 5-3805-254-20-1
ORGANIZATIONAL TROUBLESHOOTING - CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
79. DUMP BODY DOES NOT RAISE - CONTINUED.
Step 6.
Check pump-to-valve pressure hose (1) for cracked, leaking, or loose
condition.
a.
If pump-to-valve pressure hose (1) is cracked or leaking, replace
(page 2-1385).
b.
If pump-to-valve pressure hose (1) is loose, tighten using 1 1/4-
inch open-end wrench.
c.
If pump-to-valve pressure hose (1) is not cracked, leaking, or
loose, go to step 7.
Step 7.
Check lift cylinder (2) for leaking condition.
a.
If lift cylinder (2) is leaking, notify Direct Support Maintenance.
b.
If lift cylinder (2) is not leaking, go to step 8.
Step 8.
Check that dump body control lever (3) is connected.
a.
If dump body control lever (3) is not connected, connect (page
2-1367).
b.
If dump body control lever (3) is connected, go to step 9.
Step 9.
Check dump body control lever (3) adjustment (page 2-1367).
a.
If dump body control lever (3) is out of adjustment, adjust (page
2-1367).
b.
If dump body control lever (3) is not out of adjustment, go to step 10.
Step 10.
Check hydraulic oil reservoir (4) for cracked or leaking condition.
a.
If hydraulic oil reservoir (4) is cracked or leaking, notify Direct
Support Maintenance.
b.
If hydraulic oil reservoir (4) is not cracked or leaking, go to step 11.
2-412