TM 5-3805-254-20-1
PRIMARY FUEL FILTER HOUSING - CONTINUED
ACTION
LOCATION
ITEM
REMARKS
CLEANING
WARNING
Improper cleaning methods and use of unauthorized cleaning liquids or solvents can injure
personnel and cause damage to equipment. Refer to TM 9-247.
Drycleaning solvent P-D-680 is toxic and flammable. Wear protective safety goggles and gloves
and use only in a well-ventilated area. Avoid contact with skin, eyes, and clothes and do not
breathe vapors. Do not use near open flame or excessive heat. The flashpoint for type #1
drycleaning solvent is 100°F (38°C) and for type #2 is 138°F (59°C). If you become dizzy while
using cleaning solvent, get fresh air immediately, and get medical aid. If contact with eyes is
made, flush your eyes with water and get medical aid immediately.
NOTE
For more information on how to clean parts, go to General Maintenance Instructions (page 2-424).
All fuel passages in fuel filter housing and fuel hose fittings must be cleaned thoroughly.
7.
Fuel filter housing
Clean thoroughly with drycleaning solvent.
(1) and two fuel
hose fittings (2)
WARNING
Particles blown by compressed air are hazardous. Make certain the airstream is directed away
from user and other personnel in the area. Compressed air used for cleaning purposes shall not
exceed 30 psi (207 kPa). User must wear safety goggles or face shield to prevent injury to
personnel.
CAUTION
All fuel passages in fuel filter housing and fuel hose fittings must be dried thoroughly to prevent
filter damage.
8.
Fuel filter housing
Using air hose assembly and air blow gun,
(1) and two fuel
dry thoroughly.
hose fittings (2)
2-472